High Strength Corrosion Resistance
Stainless steel SS304 has beautiful appearance and good performance.
Steam trap is a device that can automatically remove non-condensable gases such as steam condensed water and air in heating equipment or steam pipes, with no steam leak.
Thermostatic (film box) steam traps are widely used in heat tracing pipelines and equipment with small displacement and low temperature requirements due to its small size, large subcooling, good energy saving effect, and low temperature resistance.
The technical advantages of VMV traps are: unique and reasonable structure and high-precision internals!
Stainless steel SS304 has beautiful appearance and good performance.
Effectively prevent pipeline impurities from entering the valve to ensure the proper operation of the trap.
All internal parts are made of 304 stainless steel, suitable for food, medicine and other industries.
The subcooling degree of the Thermostatic (film box) trap is 15℃ to remove the condensed water below the saturation temperature, and the energy saving is effective.
VMV Film Box Trap valve body and valve cover adopt 304, which can be applied in clean environment, such as medical, sanitation, food and other industries. The Film Box is stainless steel, and the condensate discharge temperature is 15-20℃. The Film Box Trap adopts a face-sealed closing system, which is noiseless, with good air exhaust ability, and makes full use of the sensible heat of condensate, and energy-saving effective.
The Film Box trap relies on the temperature difference between steam and condensate to work. When the condensed water in the pipeline stays in the pipeline due to excessively high temperature, when the temperature of the heat to be released decreases, the diaphragm in the Film Box moves to open the valve seat to discharge the condensed water. The Film Box trap can be used as an air exhaust valve.
The bellows trap continuously drains, and the normal factory product SKT16 discharges a supercooling degree of 15-20℃. If there is a supercooling degree, please indicate it when ordering. The back pressure rate of the bellows trap can reach 50% (back-end pipeline pressure/steam pressure), which is not suitable for closed recovery systems, but is suitable for pipelines and heating systems to remove condensate. In general, the safety factor is 2-3 times.
The Film Box Steam Trap can be installed at any position and arbitrarily in the pipeline or equipment. The basic configuration of the trap is shown in the figure above.